GW-7228 CR J1939/Modbus RTU Slave Gateway included CA-0910 cable(RoHS)
GW-7228 CR: Bộ chuyển đổi Gateway J1939 sang Modbus RTU
• Provide PWR / J1939 / MODBUS indication LED
• Built-in jumper to select 120 ohm terminal resistor
• Watchdog inside
• Transmission and reception of all types of J1939 messages, including PDU1, PDU2, broadcast and destination specific
• J1939 Transport Protocol for transmission and reception of large messages (9 - 1785 bytes)
• Supported BAM of Connection Management Message
• Network addresses management
• Support RS-232, RS-485 and RS-422
• interfacesSupported Modbus RTU slave protocol
• Configurable for Modbus Network ID(1~250)
• Configurable baud rates of 9600, 19200, 38400, 57600, 115200 bps
• Configurable for no, odd, or even parity and 1 or 2 stop bits
• Support Function Code 03 / 04 / 06 / 16 of Modbus functions for reading and writing J1939 Messages
Introduction
The GW-7228 is a solution that provides a protocol conversion between J1939 and Modbus RTU. For J1939 network, the GW-7228 supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. From the view of Modbus RTU network, the GW-7228 is a Modbus RTU slave to reply the request from Modbus RTU master. We provide Utility software for users to configure the parameters of J1939 / Modbus RTU of the GW-7228. The application fields can be Diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7228
• Diesel power-train applications
• In-Vehicle networks for trucks and buses
• Truck-Trailer connections
• Fleet management systems
• On Board Diagnostics
• Vehicle Automation
Specifications
LED Indicators | |
---|---|
Status | PWR / J1939 / MODBUS |
COM Ports | |
---|---|
Ports | 1 x RS-232(TXD, RXD, GND) 1 x RS-422(Tx+, Tx-, Rx+, Rx-) 1 x RS-485(D+, D-) |
Baud Rate | 9600, 19200, 38400, 57600, 115200 |
Protocol | Modbus RTU |
J1939 | |
---|---|
Transceiver | NXP 82C250 |
Ports | 1 |
Baud Rate | 250k |
Isolation | 3000 VDC power protection on CAN side, 2500Vrms photo-couple isolation on CAN bus |
Terminal Resistor | Jumper for 120 Ω terminal resistor |
Specification | ISO-11898-2, CAN 2.0A and CAN 2.0B |
Pin Assignment | C.I.A. DS-102 (CAN_H=7, CAN_L=2) |
Power | |
---|---|
Consumption | 1.5 W |
Mechanical | |
---|---|
Dimensions (mm) | 108 x 72 x 35 (H x W x L) |
Installation | DIN-Rail |
Environmental | |
---|---|
Operating Temperature | -25 ~ +75 ℃ |
Storage Temperature | -30 ~ +80 ℃ |
Humidity | 10 ~ 90% RH, Non-condensing |