Bộ chuyển đổi Gateway DeviceNet Slave sang Modbus RTU Master ICP DAS I-7242D-G CR

Thương hiệu: ICP DAS | Tình trạng: Còn hàng
Liên hệ

DeviceNet Slave to Modbus RTU Master Gateway

Gọi +84 904251826 để được trợ giúp

Bộ chuyển đổi Gateway DeviceNet Slave sang Modbus RTU Master ICP DAS I-7242D-G CR

Feature

DeviceNet Features

• Group two only server DeviceNet subscriber
• Dynamic Assembly Objects Mapping
• On-line change baud rate and MAC ID
• NS, MS and IO LED indicators
• 7-segmemt LED to show operation mode, MAC ID, baud rate and error code
• Connection supported
      ‣ "Explicit Connection"
      ‣ "Polled Command/Response" connection
      ‣ Bit-Strobed Command/Response" connection
      ‣ "Cnange-of-State / Cyclic" connection
• Configuration facilitated by the use of specific EDS files
• Dedicated Explicit message interface for full Modbus interface
• Explicit & I/O length: 240 bytes max.

Modbus RTU Features

• Maximum number of subscribers: 10 Modbus commands
• Communication speed: 1200,2400,4800,9600,19200,38400,57600 or 115200 bits/s, configured using Utility
• Data bits: 8 bits, configured using Utility
• Parity bits: None, even or odd, configured using Utility
• Stop bits: 1 or 2 bits, configured using Utility

Introduction

The I-7242D allows a master located on a DeviceNet network to enter into a dialogue with the slaves on a Modbus RTU network. It's a "Group 2 Only Slave" device in the DeviceNet network, and supports "Predefined Master/Slave Connection Set". From the view of the Modbus network, it is a Modbus RTU master which polls all the predefined data of the Modbus RTU slaves and bypasses the DeviceNet control commands to the Modbus slaves. This device is widely used in the application of building automation, remote data acquisition, environment control and monitoring, laboratory equipment & research, factory automation, etc. The I-7242D also has the utility tool which is used to configure the I-7242D's parameters and build the EDS file. Through the EDS file to the I-7242D, it is easy to apply the Modbus RTU devices in DeviceNet applications.

Application

• Control System
• Building Automation
• Factory Automation
• Distributed data acquisition

Specifications

CPU Module
CPU 80188, 40 MHz or compatible
EEPROM 16 KB
Watchdog Timer Yes
LED Indicators
Status 1 x Power
2 x DeviceNet status
COM Ports
Ports 1 x RS-232 (Utility Port)
1 x RS-485 (Modbus)
Baud Rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Protocol RS-485 (Modbus RTU)
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
DeviceNet
Controller NXP SJA1000T with 16 MHz clock
Ports 1
Connection Supported 1 connection for Explicit Messaging
1 connection for Polled I/O
1 connection for Bit-Strobe I/O
1 connection for COS/Cyclic I/O
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Jumper for 120 Ω terminal resistor
Specification Volume I, Release 2.0 & Volume II, Release 2.0
Shutdown Message Yes
Heartbeat Message Yes
Subscribe Group 2 Only Server
Power
Input Range +10 VDC ~ +30 VDC
Consumption 3 W
Mechanical
Dimensions (mm) 72 x 122 x 33 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing

Download

Datasheet

Documents

Ordering Information

I-7242D-G     CR  DeviceNet Slave / Modbus RTU Master Gateway (RoHS)

Sản phẩm đã được thêm vào giỏ hàng

Số lượng:

Tổng tiền:

Sản phẩm đã được thêm vào giỏ hàng

Phí vận chuyển: Tính khi thanh toán

Tổng tiền thanh toán: